Answers are grounded in this paper and cite their sources.
Demonstrates enhanced sensitivity for C2H2 detection in gas sensing, suggesting practical applications for remote monitoring.
Photothermal (PT) spectroscopy exhibits exceptional selectivity and high sensitivity for trace gas detection, yet developing PT gas sensors that combine fast response, high sensitivity, and practical usability remains a significant challenge. Here, we demonstrate a nested ring resonant Sagnac-enhanced PT gas sensor using a nanofiber. By inserting a nested ring resonator within the Sagnac loop, the proposed sensor reduces the full width at half-maximum of the resonance peak, thereby enhancing the cavity finesse and improving the sensitivity of PT phase modulation. With a 2 cm-long nanofiber and a resonator finesse of 73, the sensor achieves precise C₂H₂ detection featuring a noise equivalent concentration of 16 ppb, a 19 s response time, and <3% instability over 2 h. Compared to a nonresonant Sagnac interferometer using the same nanofiber, this configuration improves sensitivity by a factor of 10. By amplifying the PT effect within a short nanofiber, the sensor successfully integrates fast response with high sensitivity, overcoming the response delay typically associated with long sensing fibers. Furthermore, the sensor operates without complex wavelength-locking mechanisms, simplifying its operation and rendering it suitable for applications in remote monitoring and distributed sensing networks.
No takes yet. Share an insight, caveat, or question.
Wan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: