Key result
Unmodified GCE achieves a low Vandetanib detection limit of ~5.6x10^-9 M with excellent precision.
Effect estimate: LOD 5.58×10^-9 M
An unmodified glassy carbon electrode provides a simple, sensitive, and environmentally friendly method for the rapid electrochemical quantification of the tyrosine kinase inhibitor Vandetanib.
Simplifies Vandetanib monitoring in clinical care; extends utility of unmodified glassy carbon electrodes for TKI quantification.
This study presents a novel, simple, and cost-effective electrochemical method for the sensitive determination of Vandetanib (VAN), a clinically important tyrosine kinase inhibitor, using an unmodified glassy carbon electrode (GCE). The electrochemical behavior of VAN was investigated via cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over a wide pH range, an adsorption-controlled irreversible oxidation process involving equal numbers of protons and electrons, indicating a proton-coupled electron transfer mechanism. Optimization of experimental parameters, including pH, accumulation time, and accumulation potential, demonstrated that 0.5 M H2S04 (pH 0.3) and an accumulation time of 90 seconds provided optimal analytical performance. The DPV method exhibited excellent linearity between 2×10-8 M and 1.5×10-6 M VAN concentrations, with a low detection limit of 5.58×10-9 M. The proposed approach achieved high repeatability with relative standard deviations below 1.2%. Compared to previously reported methods involving complex electrode modifications, this work emphasizes the practicality of a bare GCE platform, eliminating the need for surface modification or surfactant addition. The method’s simplicity, sensitivity, and environmental friendliness make it a promising alternative for rapid VAN quantification.
No takes yet. Share an insight, caveat, or question.
Keles et al. (2026) studied N/A - Analytical study for quantification of anticancer drug Vandetanib. Electrochemical detection of Vandetanib using unmodified glassy carbon electrode (GCE) vs. No comparator, analytical method validation was evaluated on Limit of detection (LOD) of Vandetanib by differential pulse voltammetry (DPV) using unmodified GCE (LOD 5.58×10^-9 M). The unmodified glassy carbon electrode electrochemical method achieved a low detection limit of 5.58×10^-9 M for Vandetanib with excellent linearity and precision.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: