Key result
Significant CPET method heterogeneity across sites precludes reliable global reference ranges for VO2peak and Wpeak.
Why the study?
Existing CPET reference equations were population-specific with none spanning the human age range, highlighting the need for all-age global reference ranges for peak oxygen uptake and peak work rate.
Can global reference ranges for VO2peak and Wpeak be derived from retrospective CPET data in healthy individuals?
Can global reference ranges for VO2peak and Wpeak be derived from retrospective CPET data in healthy individuals?
Retrospective derivation of global CPET reference ranges was unsuccessful due to significant methodological heterogeneity, highlighting the need for prospective, standardized data collection.
Answers are grounded in this paper and cite their sources.
Clinicians should rely on local CPET references; leaves open global ranges pending prospective standardized data collection.
Background Cardiopulmonary exercise testing (CPET) assesses physiological responses to incremental exercise and identifies potential causes of exercise limitation. There have been several population specific reference equations published, none that span the human age range. It would be advantageous to have all-age global reference ranges. This Task Force aimed to derive Global Lung Function Initiative (GLI) reference equations for peak oxygen uptake (VO 2peak ) and peak work rate (W peak ) in healthy individuals. Methods CPET data were collected retrospectively. Generalised additive models of location, shape and scale (GAMLSS) were used to develop reference ranges, including age, sex, height, and weight as explanatory variables. The influence of geographic region, equipment, testing protocols and averaging methods for peak exercise data was also examined. Results Data from 5956 healthy individuals between 6 and 83 years across 17 sites in Europe, North and South America, and Asia were analysed. There was substantial between-subject variability in both VO 2peak and W peak , with wide confidence intervals across age groups. Heterogeneity in VO 2peak was related to geographic region, metabolic cart type, and averaging methods for peak exercise values. Controlling for these variables improved model fit but not sufficiently to be reliable predictors for reference ranges. Conclusion Significant heterogeneity in CPET testing methodology and outcomes between sites precluded the development of reference ranges for VO 2peak and W peak . This Task Force has developed a framework for prospective data collection with strictly standardised protocols and centralised data analysis to reduce variability and establish robust, clinically meaningful reference ranges for CPET outcomes.
No takes yet. Share an insight, caveat, or question.
Radtke et al. (2026) studied this question. Significant heterogeneity in CPET methods and outcomes across 17 sites precluded reliable global reference ranges for VO2peak and Wpeak despite analyzing 5956 healthy individuals.
Synapse has enriched 10 related papers. Consider them for comparative context: