Laboratory analysis reveals TaON coating enhances surface properties of titanium discs, indicating osseointegration benefits for dental implants.
Background: Tantalum in cytotoxicity tests showed no toxicity effect, as well as promoting bone regeneration through the differentiation, proliferation, mineralisation and adhesion of osteoblasts in in vitro and in vivo studies. This study aims to determine and compare the chemical composition, roughness and wettability of non-coated commercially pure titanium (CpTi) disc surfaces with CpTi discs that have been coated with tantalum oxynitride film (TaON) via a modified plasma sputtering coating technique. Methods: Two groups were tested that included the TaON-coated CpTi discs and non-coated CpTi discs. A modified reactive plasma sputtering apparatus was used for coating the CpTi discs with TaON at different time durations, i.e., 4, 6, and 8 h. The surface properties of the coated and non-coated discs were studied using X-ray diffraction (XRD) analysis, energy dispersive spectroscopy (EDS), scanning electron microscopy (SEM), and contact angle measurement. Results and Conclusions: The results showed that 8 h was the best coating duration. The XRD analysis showed the presence of a new peak in the case of the TaON-coated CpTi disc that was absent in the non-coated CpTi disc. Furthermore, the SEM analysis revealed that the TaON-coated CpTi disc showed a better distribution of surface roughness compared to the non-coated disc. The non-coated CpTi discs showed lower wettability compared to the TaON-coated CpTi discs. The result shows the importance of a TaON coat in changing the surface properties of CpTi which will be used in dental implants; this result will enhance the idea of surface treatment and its relationship with the enhancement and acceleration of bone formation around dental implants in future. The novelty of the newly modified reactive plasma sputtering technique used in this study as a coating technique for CpTi discs lies in the promising tantalum oxynitride, as Ta had no toxicity effect in cytotoxicity tests and promoted adhesion, proliferation, differentiation, the mineralisation of osteoblasts and bone regeneration in vitro and in vivo. The mean target of the work is to enhance the osseointegration of CPTi dental implants with different surface coatings including Ta oxide, nitride and oxynitride. The results of the first two coatings are already published, and the third coating technique is investigated in this study.
No takes yet. Share an insight, caveat, or question.
Farhan et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: