What you see is what you get: High degree of alignment accuracy with hand-held computer-aided technology when comparing intraoperative alignment to postoperative radiographs in direct anterior total hip arthroplasty.

View Full Paper
Ask AI
Bookmark
Share

Authors

TGThomas Matthew GeisslerMedical College of WisconsinJHJacob HallMedical College of WisconsinNKNicolas KoerberMedical College of Wisconsin

Discussion

Loading...

Member takes

Overview

Evaluates accuracy in acetabular component positioning in patients undergoing computer-navigated hip surgery, indicating significant improvements.

Key Points

  • To evaluate the precision of computer-navigated total hip arthroplasty in leg length restoration and acetabular positioning.
  • Evaluated 122 patients undergoing direct anterior computer-navigated THA.
  • Intra-operative measurements were taken using CN THA technology.
  • Post-operative radiographs were analyzed with TraumaCad® for comparison.
  • Statistical analyses included Pearson correlation coefficients.
  • 85.25% of cases restored leg length within 5 mm discrepancies.
  • 90.98% of acetabular inclination measurements were within acceptable ranges.
  • 74.59% of acetabular anteversion measurements were precise.
  • Strong correlation observed between intra-operative and post-operative measurements.

Cite This Study

Geissler et al. (2026) studied this question.

synapsesocial.com/papers/69ada804bc08abd80d5bb2b6https://doi.org/10.1177/10225536261431549
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Surgical accuracy of implant positioning in robotic-assisted versus conventional total hip arthroplasty – Experience of a Joint Replacement Centre in Hong Kong2026
  2. 2Robotic-assisted Total Hip Arthroplasty Utilizing a Fluoroscopy-guided System Produced Similar Cup Accuracy and Precision Relative to a Computerized Tomography-based Robotic Platform2024
  3. 3Robotic-arm assistance in revision total hip arthroplasty improves the accuracy of acetabular component positioning: a cadaver-based study2026
  4. 4Computer‐Assisted Total Hip Arthroplasty Improves Acetabular Prosthesis Placement Accuracy: A Multicenter, Randomized Controlled Clinical Study2024 · 1 citations