Key result
PEEP 15 associates with better V/Q mismatch in high R/I but worse in low R/I.
Why the study?
The impacts of positive end-expiratory pressure on ventilation-perfusion mismatch in the prone position relative to the supine position remained poorly understood.
Does PEEP 15 cm H2O compared to PEEP 5 cm H2O improve V/Q mismatch in patients with moderate-to-severe ARDS in supine and prone positions?
Does PEEP 15 cm H2O compared to PEEP 5 cm H2O improve V/Q mismatch in patients with moderate-to-severe ARDS in supine and prone positions?
High PEEP improves V/Q mismatch in ARDS patients with high lung recruitability in both supine and prone positions, but worsens it in prone position for those with low recruitability.
Warrants recruitability assessment before high PEEP in prone ARDS; hypothesis-generating and should not yet change practice.
High positive end-expiratory pressure (PEEP) may improve ventilation-perfusion (V/Q) mismatch in acute respiratory distress syndrome (ARDS) patients with high recruitability in supine position. However, impacts of PEEP on V/Q mismatch in prone position relative to supine position remain poorly understood. We aimed to compare PEEP effects between positions, and evaluate its relationship with lung recruitability. A total of 50 patients with moderate-to-severe ARDS were consecutively enrolled. Recruitment-to-inflation (R/I) ratio was used to measure baseline lung recruitability. V/Q mismatch, gas exchange, and respiratory mechanics were evaluated at PEEP 5 cm H 2 O and PEEP 15 cm H 2 O in supine position, followed by PEEP 5 cm H 2 O and PEEP 15 cm H 2 O in prone position. Median R/I ratio was 0.60 [0.38, 0.72], separating patients with higher and lower R/I ratio. In patients with higher R/I ratio, PEEP 15 cm H 2 O (compared to PEEP 5 cm H 2 O) reduced shunt without significantly increasing dead space in both supine and prone positions, thereby improving V/Q mismatch (supine: 30.7 [28.6, 36.8]% at PEEP 15 cm H 2 O vs.38.0 [34.9, 45.4]% at PEEP 5 cm H 2 O, P < 0.001; prone: 25.7 [21.4, 30.4]% at PEEP 15 cm H 2 O vs. 32.8 [27.5, 36.7]% at PEEP 5 cm H 2 O, P < 0.001). However, in patients with lower R/I ratio, PEEP 15 cm H 2 O (compared to PEEP 5 cm H 2 O) in supine position did not improve V/Q mismatch (37.8 [34.7, 42.1]% at PEEP 15 cm H 2 O vs. 41.3 [34.8, 45.4]% at PEEP 5 cm H 2 O, P = 0.078), as the reduction in shunt was accompanied by a significant increase in dead space; in prone position, PEEP 15 cm H 2 O significantly worsened V/Q mismatch (35.9 [28.3, 43.4]% at PEEP 15 cm H 2 O vs. 31.7 [24.3, 37.6]% at PEEP 5 cm H 2 O, P < 0.001), as it failed to reduce shunt while significantly increasing dead space. In patients with higher R/I ratio, PEEP 15 cm H 2 O improved V/Q mismatch in both supine and positions. In patients with lower R/I ratio, PEEP 15 cm H 2 O did not impact V/Q mismatch in supine position but significantly worsened it in prone position.
No takes yet. Share an insight, caveat, or question.
Zha et al. (2026) studied this question. In ARDS patients with higher recruitment-to-inflation ratio, PEEP 15 cm H₂O improved V/Q mismatch in both supine and prone positions, while worsening in lower R/I ratio patients in prone.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: