Key Points

  • The aim is to analyze a novel preheating strategy for a metal-supported solid oxide electrolysis cell system to enhance startup efficiency.
  • Developed a dynamic model of a metal-supported electrolysis cell system.
  • Proposed a three-stage cold-start strategy for ramping up temperatures safely.
  • Implemented a dual-side PID control strategy to manage heating rates.
  • Reduced total preheating time by approximately 46 minutes compared to conventional methods.
  • Improved startup efficiency by 27.7% through internal heat usage.
  • Maintained peak conduction heat transfer below 7000 W to prevent thermal shocks.

Abstract

ABSTRACT This study details the dynamic model of a metal‐supported solid oxide electrolysis cell (MS‐SOEC) system, which includes a metal‐supported stack, evaporator, heat exchanger, and associated heaters and blowers, forming an integrated electrolysis and thermal management unit. A novel, three‐stage cold‐start strategy is proposed to ensure a safe thermal ramp‐up from room temperature (303.15 K) to the target operating temperature (873.15 K). By leveraging the internal heat generated during the second stage, this strategy reduces the total preheating time by approximately 46 min and improves the startup efficiency by 27.7% compared to a conventional approach relying solely on external heaters. Adhering to these parameters effectively suppresses thermal shocks, keeping peak conduction heat transfer below 7000 W and ensuring both a safe and efficient startup. The system employs a dual‐side proportional‐integral‐derivative (PID) controller control strategy targeting a fixed heating rate of 2 K/s during the ramp‐up. The effectiveness of this control is demonstrated as the PID signals for the fuel and air‐side heaters drop from a peak of 14 200 during the initial startup to 300 and 100, respectively, at steady‐state. This drastic reduction highlights the heat exchanger's high efficiency in reclaiming reaction heat and minimizing the external power demand once operational.