PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 13, 20264 citations

Dynamic Light Scattering Method Using Derived Count Rate to Accurately Quantify Lipid Nanoparticle Concentration─A Double-Blind Study.

View Full Paper
ANAbhinandan NandrajogAAAmer Khorshed AlamJRJérémie Riou

Key Points

  • The aim is to establish a simple and accurate method for quantifying lipid nanoparticle concentration using derived count rate.
  • Utilized dynamic light scattering (DLS) with Zetasizer Nano ZS to evaluate LNP concentration.
  • Established a DCR-concentration-size map using model lipid nanoparticle batches.
  • Conducted a double-blind validation with independently formulated LNP batches.
  • The model predicted LNP concentrations with an error of approximately 4% compared to theoretical values.
  • Demonstrated consistent high precision and accuracy across formulators of varying expertise.
  • Established DCR as a robust, user-independent method for quantifying LNPs.

Abstract

The rapid advancement of nanomedicine, particularly underscored by the clinical success of lipid nanoparticle (LNP)-based vaccines, has intensified the need for simple, accurate, and widely accessible analytical techniques. A critical yet often overlooked parameter in nanoparticle development is the precise determination of the nanoparticle concentration. Conventional methods such as nanoparticle tracking analysis and electron microscopy are costly, low-throughput, and unavailable in most laboratories, creating a significant bottleneck in nanomedicine research and quality control. We investigated the potential of derived count rate (DCR), a scattered intensity parameter inherent to dynamic light scattering (DLS) when using a Zetasizer Nano ZS (Malvern Panalytical Ltd.)─an instrument available in virtually all nanomedicine laboratories─as a quantitative tool for LNP concentration analysis. A comprehensive DCR-concentration-size map was established using model LNP batches with varying concentrations. This data was used to derive a model correlating DCR, LNP size, and concentration. The model's predictive power was rigorously validated through a double-blind study involving independently formulated LNP batches with randomized compositions and unknown concentrations, done by formulators of varying expertise. The predictive model demonstrated an excellent fit. In the double-blind validation, the model predicted LNP concentrations with an error of only ∼4% compared to the theoretical values. Crucially, the method proved robust and user-independent, showing consistent high precision and accuracy across beginner, junior, and senior formulators. This study establishes DCR from standard DLS measurements as a simple, accurate, and highly accessible method for LNP quantification, bypassing the need for specialized equipment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Nandrajog et al. (2026) studied this question.

synapsesocial.com/papers/69b3ac9002a1e69014cce504https://doi.org/10.1021/acsnano.5c20971
Ask AI
Helpful
Bookmark
Share
View Full Paper