Key result
Self-expandable TAVI yields better haemodynamics than balloon-expandable TAVI in reduced LVEF despite similar clinical outcomes.
Why the study?
Does self-expandable TAVI improve ejection fraction more than balloon-expandable TAVI in adults with severe aortic stenosis and LVEF < 40%?
Cohort (n=922)
Yes
Does self-expandable TAVI improve ejection fraction more than balloon-expandable TAVI in adults with severe aortic stenosis and LVEF < 40%?
Answers are grounded in this paper and cite their sources.
In patients with severe aortic stenosis and LVEF < 40%, both self-expanding and balloon-expandable TAVI valves provide similar sustained improvements in ejection fraction and clinical outcomes, despite better haemodynamics with self-expanding valves.
BACKGROUND: In severe aortic stenosis with reduced left ventricular ejection fraction (LVEF), transcatheter aortic valve implantation (TAVI) improves systolic function. Self-expanding valves (SEV) show haemodynamic advantages over balloon-expandable valves (BEV), but whether this yields greater recovery of left ventricular function remains uncertain. OBJECTIVES: To compare change in ejection fraction between BEV and SEV in adults with LVEF < 40% undergoing TAVI, and to assess haemodynamics and clinical outcomes at 30 days and 12 months. METHODS: Observational cohort using a national registry of adults with LVEF < 40% and no prior myocardial infarction, coronary bypass, or more-than-moderate mitral regurgitation. Nearest-neighbor matching balanced annular perimeter, diameters, and calcification. Echocardiographic outcomes and major adverse cardiac and cerebrovascular events (MACCE) were assessed at 30 days and 12 months. Subgroup analyses stratified patients by annular perimeter ≤ 73.5 or > 73.5 mm. RESULTS: Of 922 patients, 574 received a BEV and 348 a SEV. Ejection fraction improved by 30 days and was maintained at 12 months, with no between-group difference. Haemodynamics favored SEV, with lower mean gradients at 30 days and 12 months (both p < 0.001). Clinical outcomes, including MACCE, were similar at 30 days and 12 months, and findings were consistent in small and large annulus strata. CONCLUSIONS: In patients with reduced LVEF, TAVI produced sustained improvement in ejection fraction irrespective of valve platform, and SEV conferred a haemodynamic advantage without differences in ejection fraction or clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Dababneh et al. (2026) conducted a cohort in severe aortic stenosis with reduced left ventricular ejection fraction (n=922). Self-expanding valves (SEV) vs. Balloon-expandable valves (BEV) was evaluated on change in ejection fraction. Self-expanding valves conferred a haemodynamic advantage over balloon-expandable valves but resulted in similar improvements in ejection fraction and clinical outcomes at 12 months.
Synapse has enriched 10 related papers. Consider them for comparative context: