PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 14, 2026Proceedings of the National Academy of Sciences2 citationsOpen Access

A soft electrode array with reconfigurable hydrogel interfaces for high-fidelity neurophysiological monitoring during craniotomy

View Full Paper
GYGanguang YangBPBo PangHGHangyu Gong

Key Points

  • To improve monitoring of neural signals during craniotomy with a soft electrode array and hydrogel interfaces.
  • Developed a soft electrode array with reconfigurable hydrogel interfaces.
  • Utilized a strategy for disassembly and replacement of hydrogel layers for better performance.
  • Tested in animal models during craniotomy and traumatic brain injury scenarios.
  • Maintained low impedance and high signal-to-noise ratio in repositioning tests.
  • Recorded consistent somatosensory evoked potentials with dynamic tracking of responses.
  • Efficiently elicited motor evoked potentials with low stimulation currents.

Abstract

Achieving accurate monitoring of electrophysiological activity from the brain cortex is critical for preventing postoperative neurological deficits during craniotomy. However, current technologies face profound challenges in enabling consistent high-quality neural signal acquisition due to complex intracranial environments (e.g., wet/fragile brain surfaces and surgical instrument interference). Here, we develop a soft electrode array with reconfigurable hydrogel interfaces for sustainable high-fidelity monitoring of electrophysiological states from the functional brain cortex throughout neurosurgical procedures. Specifically, we propose a solution-triggered reconfiguration strategy to implement the repeated disassembly/replacement of hydrogel interface layers on electrodes, ensuring consistently superior recording and stimulation properties. Furthermore, through modification with cationic hydrogel microspheres, the hydrogel interface demonstrates strengthened wet adhesion and antiswelling performances, creating robust hydrogel/brain coupling to minimize motion artifacts. In craniotomy of animal models, the electrode array maintains low impedance and high signal-to-noise ratio during repeated repositioning tests through hydrogel interface reconfiguration. In traumatic brain injury models, the electrode array can record consistent high-quality somatosensory evoked potential with dynamic tracking of potential amplitude and latency changes in sensory areas. Quantitative assessments in nerve block experiments verify that the soft electrode array can efficiently elicit motor evoked potentials in motor areas with low stimulation currents. The proposed soft electrode array represents a promising platform for sustainable high-fidelity electrophysiological monitoring. The hydrogel interface design strategy provides an effective approach for developing reconfigurable devices in biomedical applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yang et al. (2026) studied this question.

synapsesocial.com/papers/69b4ad8d18185d8a39801061https://doi.org/10.1073/pnas.2533145123
Ask AI
Helpful
Bookmark
Share
View Full Paper