This project improves chromaticity coordinate quality in automotive LED packages, indicating significant reliability gains.
Purpose: The purpose of this paper is to improve the chromaticity coordinate quality of white LED packages for automobiles that require high quality and reliability.Methods: The project follows the structured methodology of the Six Sigma DMAIC Roadmap, which consists of Define, Measure, Analyze, Improve and Control phases.Results: A CTQ is determined based on COPQ analysis, and a process map and a XY matrix are utilized for selecting process input variables. Three vital Few Xs are identified through data analysis; amount to mix at one time, deviation by head pumps, and deviation by production magazines, and process improvements are performed for each of the three vital Few Xs.Conclusion: The improved process conditions for the three vital Few Xs are applied to the production line, and the results show that the percent defective of chromaticity coordinate has improved from 1.59% to 0.63% and a financial effect of about 50 million won per year is obtained.