A case report demonstrates successful lung isolation using a microlaryngeal tube in a patient with intraoperative hemorrhage, suggesting its potential as a rescue tool.
A 29-year-old female (165 cm, 68 kg) with a 4.9 cm × 3.2 cm × 3.5 cm carcinoid tumour in the right intermediate bronchus underwent right bilobectomy. Despite pre-operative computed tomography showing anatomical distortion warranting fibre-optic guidance, blind placement of a 35-Fr left-sided double-lumen tube was attempted. We inadvertently placed the tube into the right bronchus, traumatising the tumour and causing significant haemorrhage. After a failed 9-Fr Cohen bronchial blocker placement, successful lung isolation was achieved using a 5.0-mm microlaryngeal surgery tube placed under fibreoptic guidance. This represents the first reported adult use of a microlaryngeal tube for emergency lung isolation following double-lumen tube-induced haemorrhage. One-lung ventilation was maintained for 4.5 h without complications. The case demonstrates that pre-operative anatomical distortion mandates fibreoptic-guided double-lumen tube placement and highlights the microlaryngeal tube as a viable rescue option when conventional devices fail. Thoracic anaesthesiologists should maintain proficiency with multiple lung isolation techniques and have immediate access to alternative devices.
No takes yet. Share an insight, caveat, or question.
Maurya et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: