Key result
Transcatheter removal of mitral bioprosthetic vegetation using double SENTINEL filters achieves extended embolic protection.
Why the study?
Prior transcatheter removals of left-sided valvular vegetations were performed without or with partial cerebral embolic protection.
Describes a novel transcatheter technique using double embolic protection filters to reduce cerebral embolic risk during the removal of left-sided valvular vegetations.
May lower cerebral embolic risk in select patients; hypothesis-generating for dual-filter protection in transcatheter vegetation removal.
Abstract Transcatheter removal of right-sided vegetations has been reported, and anecdotal reports of transcatheter removal of left-sided valvular vegetations are present in the literature, but these procedures were done without or with partial cerebral embolic protection. We report a case of transcatheter removal of a vegetation from a contemporary mitral bioprosthetic valve and describe a novel technique of obtaining extended embolic protection using double SENTINEL (Boston Scientific) filters.
No takes yet. Share an insight, caveat, or question.
Nandhakumar et al. (2026) studied this question. Transcatheter removal of vegetation from a mitral bioprosthetic valve using double SENTINEL filters achieved extended embolic protection.