March 16, 2026Semiconductors0 citations

Low-Power, High-Sensitivity Biosensor in Biomedical Diagnosis Incorporating SiGe-Pocket-P-I-N-V-TFET

View Full Paper
SBShankar Kumar BhartiAKAkhilesh KumarAKAbhishek Kumar

Key Points

  • The research aims to design and assess a label-free biosensor utilizing a unique SiGe pocket-based V-TFET for biomolecule detection.
  • Design of a biosensor based on a dielectrically modulated SiGe pocket V-TFET.
  • Assessment of sensitivity to neutral and charged biomolecules.
  • Measurement of various electrical metrics like drain current and threshold voltage.
  • Maximum ON-current detected was 4.90 × 10–5 A/µm at a dielectric constant of 12.
  • Notable OFF-current measured at 2.86 × 10–18 A/µm.
  • Biosensor sensitivity readings obtained were 3.90 × 106 for drain current and 8.46 × 105 for transconductance.

Abstract

The article presents the design and investigation of a label-free biosensor based on a dielectrically modulated SiGe pocket based intrinsic channel Vertical Tunnel Field-Effect transistor (V-TFET). The proposed biosensor can detect different biomolecules such as protein, APTES (3-aminopropyltriethoxysilane), apomyoglobin, and gelatin. Different electrical metrics, such as drain current (ID), electric field (Ef), threshold voltage (VTH), electron band-to-band tunneling (eBTBT) rate, and drain current sensitivity (Scurrent), significantly changed while different biomolecules having different dielectric constants were incorporated. Additionally, both neutral, and charged biomolecules have been studied to determine the sensitivity of biosensor. A charged biomolecule is examined over a range of positive and negative charge densities with a dielectric constant of κ = 12. At κ = 12 (gelatin), the biosensor able to detect maximum ON-current of 4.90 × 10–5 A/µm and an OFF-current of 2.86 × 10–18 A/µm with decent SS (12.494 mV/dec). Finally, both neutral and charged biomolecules have been studied to determine the biosensor’s sensitivity of κ = 12. The proposed biosensor obtained drain current and transconductance sensitivity readings of 3.90 × 106 and 8.46 × 105, respectively. Lastly, the proposed biosensor device has been shown to produce notable improvement sensitivity and improved SS in comparison to other studies published.