Key result
Skin thickness ≤ 3.3 mm over CIEDs is linked to increased all-cause mortality.
Why the study?
Does skin thickness ≤ 3.3 mm over CIEDs predict all-cause mortality and device-related infections in patients with CIEDs?
Cohort (n=96)
Does skin thickness ≤ 3.3 mm over CIEDs predict all-cause mortality and device-related infections in patients with CIEDs?
Skin thickness ≤ 3.3 mm over CIEDs is an independent predictor of increased all-cause mortality and progressively declines over time.
Answers are grounded in this paper and cite their sources.
May prompt routine skin thickness measurement in CIED clinics; extends simple prognostic tools but leaves open outcome impact.
BACKGROUND: Skin thinning over cardiac implantable electronic devices (CIEDs) is frequently observed; however, its clinical implications and temporal progression remain unclear. This study aimed to investigate the clinical significance of skin thickness over CIEDs by examining its association with adverse outcomes, including all-cause mortality and device-related infections, and evaluating its temporal changes and associated clinical factors. METHODS: This study included 96 patients who underwent ultrasonographic measurement of skin thickness over CIEDs between June 2020 and June 2021. Adverse outcomes were monitored through August 2023. Of those, 34 patients had follow-up ultrasonography to assess temporal changes in skin thickness. RESULTS: Among 34 patients with repeated measurements, skin thickness significantly declined over a median of 42 (IQR: 41-44) months (p = 0.001), and thinning was correlated with changes in hemoglobin levels (r = 0.392, p = 0.024). During a median follow-up of 32 (IQR: 11-34) months, patients with skin thickness ≤ 3.3 mm (thin group) had significantly higher all-cause mortality than those with a thickness > 3.3 mm (normal group) (log-rank p < 0.001). In multivariable Cox regression analysis, skin thickness ≤ 3.3 mm remained an independent predictor of mortality (HR 2.42; 95% CI, 1.01-5.80; p = 0.046). Device-related infections were more frequent in the thin group (8%) than in the normal group (2%), but the difference was not statistically significant. CONCLUSIONS: Skin thickness over CIEDs progressively declined over time and was significantly correlated with hemoglobin levels. In addition, skin thickness ≤ 3.3 mm was independently associated with increased all-cause mortality.
No takes yet. Share an insight, caveat, or question.
Yonehara et al. (2026) conducted a cohort in Cardiac implantable electronic devices (CIEDs) (n=96). Skin thickness ≤ 3.3 mm vs. Skin thickness > 3.3 mm was evaluated on All-cause mortality (HR 2.42, 95% CI 1.01-5.80, p=0.046). Skin thickness ≤ 3.3 mm over cardiac implantable electronic devices was independently associated with increased all-cause mortality compared to thickness > 3.3 mm.
Synapse has enriched 10 related papers. Consider them for comparative context: