Key result
Cross-lead attention transformer with GAN oversampling detects ECG arrhythmias with ~99.7% accuracy.
Why the study?
Accurate detection of cardiac arrhythmias from electrocardiograms remains challenging for rare rhythm classes due to class imbalance and morphological variability.
Does a hybrid deep learning framework with cross-lead transformers and GAN oversampling accurately detect cardiac arrhythmias across different ECG lead configurations?
Does a hybrid deep learning framework with cross-lead transformers and GAN oversampling accurately detect cardiac arrhythmias across different ECG lead configurations?
A novel deep learning framework using cross-lead attention transformers and GAN oversampling provides highly accurate, interpretable, and deployable ECG arrhythmia detection.
May enhance clinical arrhythmia detection across ECG leads; extends deep learning with robust performance on external validation.[[1]](https://www.mdpi.
Accurate detection of cardiac arrhythmias from electrocardiograms remains challenging for rare rhythm classes due to class imbalance and morphological variability. We present a hybrid deep learning framework combining per-lead convolutional encoders with a cross-lead transformer that models relationships across different lead signals through self-attention, accepting variable lead configurations. To address minority-class scarcity, a generative adversarial network synthesizes physiologically plausible beat segments for underrepresented arrhythmias. Attention-based visualizations localize influential waveform regions aligned with clinically meaningful structures. Post-training pruning and INT8 quantization enable efficient deployment with minimal performance loss. Extensive experiments on the MIT-BIH Arrhythmia Database across sixteen heartbeat classes from two-lead recordings yield exceptional results over ten independent runs: accuracy of 99.67%, F1-score of 99.66%, and AUC of 99.8%. External validation on the ECG5000 single-lead dataset and the St Petersburg INCART twelve-lead dataset confirms robust generalizability with F1-scores of 97.6% and 98% respectively. Our framework delivers accurate, interpretable, stable, and deployable arrhythmia detection across diverse clinical settings.
No takes yet. Share an insight, caveat, or question.
Tibermacine et al. (2026) studied this question. A cross-lead attention transformer with GAN oversampling detected ECG arrhythmias with 99.67% accuracy and 99.8% AUC, maintaining robust F1-scores of 97.6% to 98% in external validation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: