Collaboration develops UV imager to evaluate geological samples on Venus, suggesting feasibility for future exploration.
GE Aerospace Research, in collaboration with NASA Glenn Research Center (NASA Glenn) and Ohio Aerospace Institute (OAI), are designing and packaging a UV Imager using silicon carbide (SiC) electronic components to demonstrate feasibility of an ultraviolet (UV) near-field image camera for imaging geological samples on the surface of Venus. The SiC imager is sensitive to UV light from a power source and will use either reflected light or fluorescence from surface geological formations. The target operating environment is 500°C for 60 days with a target image resolution of 1 mm per pixel at 0.5 m distance. Packaging materials and devices were selected that have previously been tested at 500°C in air and submitted to a simulated Venus environment (460°C, 1344 psia, and corrosive gases) for 10 day intervals. The materials were evaluated for electrical and chemical degradation after exposure. Chemical degradation was evaluated using X-ray photoelectron spectroscopy (XPS) and hard X-ray photoelectron spectroscopy (HAXPES). Results are presented.