Key result
Bedside upper arm ultrasound accurately predicts CT-derived L3 subcutaneous adipose tissue-to-muscle ratio.
Why the study?
A subcutaneous adipose tissue-to-muscle mass ratio may be more informative than separate evaluations, but which extremity ultrasound measurement points best predict the gold-standard L3 CT ratio was unknown.
Does extremity ultrasound predict the subcutaneous adipose tissue-to-muscle ratio measured by CT at the L3 level in hospitalised patients?
Does extremity ultrasound predict the subcutaneous adipose tissue-to-muscle ratio measured by CT at the L3 level in hospitalised patients?
Bedside extremity ultrasound, particularly at the anterolateral upper arm, can non-invasively predict the CT-derived subcutaneous adipose tissue-to-muscle ratio at the L3 level.
May enable bedside body composition assessment without CT in hospitalized patients; extends L3 sarcopenia evaluation to point-of-care ultrasound.
Background/Objectives: A ratio of subcutaneous adipose tissue to muscle mass may be more informative than defining low subcutaneous adipose tissue and muscle mass separately. The objective of this study was to determine which ultrasound measurement points in the upper and lower extremities predict the subcutaneous adipose tissue (SAT)-to-muscle ratio as measured by gold-standard computed tomography (CT) at the third lumbar vertebra (L3) level. Methods: Two hundred hospitalised patients (41% female; median (Q1–Q3) age: 61.3 (51.0–70.1) years) who underwent an abdominal CT scan for any clinical reason within 48 h prior to extremity ultrasound were included in this prospective observational study conducted from 2017 to 2019. Ultrasound measurements of subcutaneous adipose tissue and muscle thickness were obtained at three measuring points on the thigh and two on the upper arm. On the CT scan at the L3 level, subcutaneous (SAT) and visceral adipose tissue and skeletal muscle area were measured. A linear LASSO (Least Absolute Shrinkage and Selection Operator) model was used to identify which ultrasound sites best predicted the CT L3 SAT-to-muscle ratio. Results: Height, weight, sex, SAT-to-muscle ratio at four ultrasound measuring points and abdominal circumference predicted the CT SAT-to-muscle ratio in the LASSO model (R2 = 0.70; cross-validated R2 = 0.63; p values are not reported in LASSO regression and R2 is used instead). The upper-arm anterolateral ultrasound site most strongly influenced the CT SAT-to-muscle ratio (estimate × standard deviation of predictor: 0.24). Conclusions: The CT SAT-to-muscle ratio at the L3 level can be predicted non-invasively using bedside ultrasound, particularly at the anterolateral measuring point of the upper arm. Bedside ultrasound assessment of the ratio of subcutaneous adipose tissue to muscle on the anterolateral upper arm provides a within-patient comparison of body compartments.