This experimental study shows high-efficiency impurity removal in tellurium through simulation-assisted zone refining, indicating effective purification methods.
The effect of temperature on molten zone length was investigated through simulation to optimize the control of molten zone length during the experimental process. The temperature gradient distribution within the molten zone during zone refining was simulated using COMSOL Multiphysics software and experimentally validated. The simulated molten zone length showed good agreement with the actual measured length. The experimental study of tellurium purification by zone refining was conducted under the following conditions: three passes of zone refining, a hydrogen flow rate of 0.5 L/min, and molten zone movement speeds of 0.5 and 1.0 mm/min. The results demonstrated that the removal efficiencies of impurities such as Ca and Cu exceeded 95%, while the removal efficiency of phosphorus (P) reached over 70%. And the purity of tellurium reached 6N.
No takes yet. Share an insight, caveat, or question.
Tian et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: