Examines a high-frequency power supply, revealing its performance in induction heating applications.
This paper examines a high-frequency power supply with a transformerless matching circuit. A method is developed for calculating the matching circuit parameters and parameters that must be considered when selecting the circuit main power components—inverter transistors and the matching circuit capacitor. For a specific load case, an inductor model is developed, and the active and inductive reactances is calculated for use in the high-frequency power supply model. To study the power supply and demonstrate its performance, a model for a nominal load power of 3 kW is developed. The model utilizes detailed models of silicon carbide transistors to estimate their thermal losses. The results of the model operation with varying load parameters are presented.