Key result
Performing critical ICU procedures linked to significant physiologic stress and a ~50% drop in trainee RMSSD.
Why the study?
Data on physiologic stress measured by heart rate variability in pediatric critical care trainees performing real-time procedures were limited.
Does performing high-stakes ICU procedures increase physiologic stress measured by HRV in pediatric critical care trainees compared to baseline?
Does performing high-stakes ICU procedures increase physiologic stress measured by HRV in pediatric critical care trainees compared to baseline?
Pediatric ICU trainees experience significant increases in physiologic stress, as measured by heart rate variability, when performing emergent procedures.
Answers are grounded in this paper and cite their sources.
May warrant stress mitigation training for pediatric critical care trainees; leaves open whether interventions improve procedural outcomes.
Introduction: Heart rate variability (HRV) is an objective measure of physiologic stress. Although HRV has been studied in physicians during simulated procedures, data on pediatric critical care trainees performing real-time procedures are limited. This study aimed to: 1) quantify physiologic stress during high-stakes intensive care unit (ICU) procedures compared to baseline and 2) compare subjective and objective measures of stress experienced while performing these procedures. Methods: This prospective observational study enrolled pediatric ICU trainees performing clinically indicated intubations, arterial lines, and central venous lines (CVL). Participants wore a Hexoskin vest to record continuous ECG data for HRV analysis. Baseline HRV was compared to HRV during procedures using a paired t-test/Wilcoxon rank test. Standard HRV metrics were calculated, including the Low-Frequency to High-Frequency Ratio (LF/HF), RMSSD (Root Mean Square of Successive Differences), Standard Deviation (SD) of NN intervals (SDNN), and SD2/SD1. Subjective stress (e.g. workload) was measured with the validated NASA-Task Load Index (NASA-TLX). Associations between HRV and NASA-TLX scores were assessed using the Pearson/Spearman’s rank correlation coefficient. Results: Study participants included 1 resident (6.3%) and 7 fellows (93.8%) who performed 16 procedures (2 intubations, 7 CVLs, 7 A-lines) on 13 patients. There was a statistically significant change in mean trainee procedural HRV compared to baseline for all parameters except LF/HF reflecting increased sympathetic tone and parasympathetic withdrawal. Comparison of the mean baseline vs. procedural HRV was notable for increased LF/HF (4.79 vs. 6.67; p=0.07), increased SD2/SD1 (2.76 vs. 4.06; p=< 0.001), decreased RMSSD (34.53 vs. 17.28; p=< 0.001) and decreased SDNN (47.12 vs. 34.22; p=0.003) consistent with increased procedural stress. The mean NASA-TLX score (out of 100) was 55.16 (SD 17.38) reflecting high workload (e.g. stress). The difference between NASA-TLX scores and percent change in HRV during procedures was not statistically significant. Conclusions: Trainees experience increased physiologic stress when performing emergent procedures in the ICU. Future directions aim to increase sample size and correlate HRV measures to procedural success and difficulty.
No takes yet. Share an insight, caveat, or question.
Engelbrecht et al. (2026) studied this question. Pediatric ICU trainees performing critical procedures demonstrated significant physiologic stress, marked by decreased RMSSD and SDNN from baseline.
Synapse has enriched 10 related papers. Consider them for comparative context: