Experimental study evaluates shear resistance in externally strengthened beams, indicating effective reinforcement strategies.
Fabric-reinforced cementitious matrix (FRCM) systems have been developed as strengthening systems that offer several advantages over fiber-reinforced polymer systems, including improved fire resistance and compatibility with wet surfaces. This paper presents the results of an experimental study on the shear resistance contribution of RC beams externally strengthened with FRCM systems. Shear tests were performed on 12 RC beams. The experimental variables included different types of textile grids (distinguished by impregnation type and surface coating), various strengthening configurations (side-bonding and U-wrapping), and different spacings of internal transverse reinforcement. The results showed that external strengthening with FRCM composites effectively enhanced the shear strength of RC beams. The measured shear resistance contribution varied depending on the textile grid type and was significantly influenced by both the mechanical properties of the textile grid and the amount of internal transverse reinforcement. In particular, the shear strength contribution of the FRCM composite increased with increasing axial stiffness ratio between the external FRCM reinforcement and the internal transverse reinforcement. Finally, a comparison with prediction models from previous studies revealed that the experimentally measured FRCM shear contributions were higher than those predicted theoretically.
No takes yet. Share an insight, caveat, or question.
Jo et al. (2026) studied this question.