Answers are grounded in this paper and cite their sources.
Designing a D-type endoscope reveals improved imaging quality in laryngeal examinations, suggesting ergonomic benefits.
基于国内外圆管喉镜在临床使用中因接触喉部而产生异物感的问题,提出一种在不影响成像前提下符合人体工学的D型机械结构,设计并制造了一款用于喉部检查的医疗硬性D型内窥镜。设计的内窥镜系统提高了物镜的相对孔径,并采用一种与其匹配的中继系统,全视场角为60°,视向角为90°,中继系统采用双远心结构,工作长度为170 mm,内窥镜系统的像方分辨率在94 lp/mm处,MTF大于0.2。当物距为10 mm时,物方分辨率为52.58 lp/mm,物方角分辨率为11.45 c/(°)。实验测试结果表明:设计的内窥镜在减少与喉部接触面积的条件下,可提供清晰的图像,满足预期指标和实际使用需求。
No takes yet. Share an insight, caveat, or question.
BAI et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: