Key result
Wearable radial artery tonometry proves feasible for continuous cuffless BP monitoring under physiological stress.
Why the study?
Does wearable radial artery tonometry accurately measure continuous beat-to-beat blood pressure compared to a Finapres reference device in healthy adults?
Observational (n=20)
Does wearable radial artery tonometry accurately measure continuous beat-to-beat blood pressure compared to a Finapres reference device in healthy adults?
Wearable radial artery tonometry demonstrates reliable beat-to-beat blood pressure tracking during dynamic physiological stress conditions, supporting its feasibility for continuous cuffless monitoring.
Answers are grounded in this paper and cite their sources.
Provides clinicians a cuffless option for continuous BP monitoring; extends research into physiological stress recordings.
OBJECTIVE: To evaluate the feasibility of continuous beat-to-beat blood pressure (BP) monitoring using radial artery tonometry under controlled dynamic conditions in healthy adults. METHODS: Twenty healthy adults participated in laboratory recordings that included seated rest and controlled dynamic challenges, including isometric handgrip, cold pressor testing, and inspiratory threshold loading. Beat-to-beat BP was estimated from the tonometry waveform, with periodic cuff-anchored drift correction and automated signal quality indices applied to exclude corrupted segments. Tonometric BP measurements were compared against a Finapres continuous noninvasive reference device. RESULTS: Fourteen recordings met the stability criterion (94.2 ± 6.3% data retention, approximately 42,000 accepted beats). Agreement with the reference was strong, with Pearson correlation coefficients of 0.933, 0.945, and 0.954 for systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP), respectively. Corresponding mean absolute differences were 7.1 ± 5.7, 2.5 ± 2.5, and 3.8 ± 3.0 mmHg. CONCLUSION: Radial artery tonometry with periodic drift correction and signal quality filtering demonstrated reliable beat-to-beat BP tracking during extended recordings that included controlled dynamic BP changes. SIGNIFICANCE: These findings support the feasibility of wearable radial artery tonometry for continuous cuffless BP monitoring and provide a reproducible basis for evaluating long-duration tonometric recordings under physiological stress conditions.
No takes yet. Share an insight, caveat, or question.
Almadi et al. (2026) conducted an observational in Healthy adults (n=20). Wearable radial artery tonometry vs. Finapres continuous noninvasive reference device was evaluated on Agreement with reference device for systolic BP, diastolic BP, and mean arterial pressure (Pearson correlation coefficients of 0.933, 0.945, and 0.954 for SBP, DBP, and MAP). Wearable radial artery tonometry showed strong agreement with a reference device for continuous blood pressure monitoring, with mean absolute differences of 7.1 mmHg for SBP and 2.5 mmHg for DBP.