Key result
Dobutamine iFR detects dynamic stenosis in an anomalous RCA despite normal dobutamine FFR.
Why the study?
Specific clinical scenarios favoring instantaneous wave-free ratio over fractional flow reserve during dobutamine challenge for hemodynamic assessment of anomalous aortic origin of a right coronary artery remain unclear.
Does iFR-dobutamine detect stress-induced ischemia differently than FFR-dobutamine in a pediatric patient with R-AAOCA?
Does iFR-dobutamine detect stress-induced ischemia differently than FFR-dobutamine in a pediatric patient with R-AAOCA?
This case highlights a specific scenario in anomalous coronary arteries where iFR-dobutamine may detect ischemia despite a normal FFR-dobutamine reference standard.
Should not yet alter practice for pediatric R-AAOCA; hypothesis-generating regarding iFR-dobutamine sensitivity to dynamic ischemia versus FFR.
Anomalous aortic origin of a right coronary artery (R-AAOCA) can cause stress-induced ischemia owing to dynamic stenosis of the intramural course. While fractional flow reserve during dobutamine challenge (FFRDobutamine) is the reference standard for hemodynamic assessment, specific scenarios favoring instantaneous wave-free ratio (iFR) over FFR remain unclear.
No takes yet. Share an insight, caveat, or question.
Stark et al. (2026) studied this question. Dynamic stenosis of an anomalous right coronary artery in an 11-year-old athlete resulted in an abnormal iFR-dobutamine despite a normal FFR-dobutamine.