March 28, 2026Energies2 citationsOpen Access

Physiochemical Properties Investigation of Thermal–Moisture-Aged Low Voltage PVC Cable Insulation

View Full Paper
ARAttique Ur RehmanMZMuhammad ZeeshanUAUsman Ali

Key Points

  • This research aims to explore how thermal and moisture aging affects the properties of PVC insulation in low voltage photovoltaic cables.
  • Conducted accelerated aging design simulating real operating conditions in hot, humid climates.
  • Performed thermal aging at 90 °C for five cycles followed by moisture injection.
  • Utilized broadband dielectric spectroscopy, FTIR analysis, and Shore D hardness measurements for evaluation.
  • Observed a 5% increase in dielectric dissipation factor and 7% increase in hardness at 100 kHz.
  • Noted a 68% decrease in the carbonyl index and a 75% decrease in the hydroxyl index.
  • Identified three aging stages: early thermo-oxidation, mid-stage dehydrochlorination, and late-stage chain scission.

Abstract

This study investigates the combined effects of thermal and moisture aging on PVC-insulated low voltage (LV) photovoltaic (PV) cables using an accelerated-aging design to represent realistic PV operating conditions commonly encountered in hot and humid climates. Thermal aging was carried out at 90 °C for five aging cycles, with each thermal cycle followed by controlled moisture injection to simulate moisture stress. The degradation behavior was evaluated using broadband dielectric spectroscopy, FTIR analysis, and Shore D hardness measurements. Changes in dielectric dissipation factor (tanδ) and real permittivity (ε′) were analyzed over a wide frequency range, with 100 kHz selected for its high sensitivity to aging-induced oxidation-related dipolar and interfacial polarization mechanisms. Degradation indices (DI) and degradation rates (DR) were derived from tanδ and correlated with mechanical and chemical changes. The results showed a 5% and 7% increase in tanδ at 100 kHz and in hardness, respectively, with decreases of 68% and 75% in the carbonyl and hydroxyl indices, respectively. Three distinct aging stages were identified: early thermo-oxidation with limited functional impact; mid-stage dehydrochlorination and moisture interaction; and late-stage chain scission, plasticizer loss, and insulation stiffening. The findings demonstrate the importance of climate-specific aging assessment and confirm the effectiveness of integrated electrical, mechanical, and chemical diagnostics for PV cable condition monitoring.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Rehman et al. (2026) studied this question.

synapsesocial.com/papers/69c771688bbfbc51511e15c2https://doi.org/10.3390/en19071628