Answers are grounded in this paper and cite their sources.
Audit reveals persistent under-triage risks in urgent cases of symptom assessment tools, suggesting safety improvements are needed.
Introduction: Large language models are increasingly discussed as tools for patient-facing symptom assessment, but safe self-triage depends on the concrete next action recommended to the user rather than on generic urgency language alone. We audited whether a commercially deployed general-purpose model could map Japanese symptom vignettes to clinically acceptable self-triage actions across low-risk and urgent scenarios. Methods: From a bank of 60 synthetic lay personas and 30 Japanese symptom vignettes, we constructed three predefined slices, each comprising 24 persona-vignette pairs: a mild slice (sev1_24), an intermediate non-red-flag slice (nonredflag24), and an urgent red-flag slice (redflag24). Outputs were restricted to a 10-category action codebook ranging from watchful waiting (A0) to ambulance activation (A9). The audited model was gpt-4o-mini accessed through the OpenAI Responses API. Narrative and structured prompts were compared under near-deterministic decoding (temperature 0.0, top_p 1.0) and stochastic decoding (temperature 1.0, top_p 0.95). A response-schema condition was also evaluated. Acceptable action ranges were defined by an explicit operational reference policy informed by Japanese emergency-care and triage literature. Results: A total of 3,342 valid outputs were analyzed. Hard under-triage and hard over-triage were absent in the mild and non-red-flag slices across all tested conditions. In contrast, the red-flag slice showed near-universal hard under-triage of the primary action: 100.0% for both prompts under near-deterministic decoding, 100.0% for P1 and 99.7% for P2 under stochastic prompt-only decoding, and 100.0% for both prompts under stochastic response-schema decoding. Near-deterministic decoding improved run-to-run modal agreement, but this reproducibility gain did not improve urgent-case safety. Response-schema enforcement often improved agreement relative to stochastic prompt-only execution, yet in some urgent conditions, it increased the proportion of escalation recommendations that still remained below the hard minimum. Conclusion: In this safety audit, gpt-4o-mini was conservative in low-risk cases but unsafe in urgent cases because urgency was expressed mainly through timing and escalation fields rather than through an appropriately urgent primary action. Better reproducibility under near-deterministic decoding did not translate into safer self-triage. Medical audits of LLM self-triage systems should report primary-action safety, auxiliary urgency cues, decoding configuration, and schema mode separately.
No takes yet. Share an insight, caveat, or question.
Yuusuke Harada (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: