PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 29, 2026SHILAP Revista de lepidopterología0 citationsOpen Access

Comparison of the efficacy of spiral CT combined with advanced multiplanar reconstruction in detecting the progression of pneumoconiosis

View Full Paper
YLYa LiuSinopec (China)NZNan ZhuAnyang Hospital of Traditional Chinese MedicineHSHong-Zhi SunThird People's Hospital of Hefei

Key Points

  • The aim is to assess the effectiveness of multiplanar reconstruction in analyzing bronchovascular changes to stage pneumoconiosis.
  • Analyzed CT data from 65 patients with confirmed pneumoconiosis.
  • Used multiplanar reconstruction to measure bronchial and vascular parameters.
  • Employed Lasso regression for feature selection.
  • Evaluated diagnostic efficacy with ROC curves.
  • Stage III showed significantly higher bronchial wall thickness-to-diameter ratio, vascular bifurcation angle variation index, and fractal dimension than stage I.
  • The cuffing sign was more prevalent in stage II compared to stage I.
  • Combined parameters achieved an AUC of 0.911, with sensitivity of 92.3% and specificity of 88.6%.
  • Positive correlation between vascular bifurcation angle variation and vascular calcification score.
  • Negative correlation between fractal dimension and lung volume.

Abstract

Objective To investigate the value of multiplanar reconstruction (MPR) technology in the quantitative analysis of bronchovascular bundle (BVB) for staging pneumoconiosis. Methods We retrospectively analyzed CT data from 65 patients with confirmed pneumoconiosis (42 stage I, 16 stage II, 7 stage III) at Hefei Third People’s Hospital between January 2020 and March 2025. MPR was used to measure the bronchial wall thickness-to-diameter ratio (WT/D), the vascular bifurcation angle variation index (AVI), and the peribronchial fractal dimension (FD). Feature parameters were selected using Lasso regression, and diagnostic efficacy was evaluated using ROC curves. Results Significant intergroup differences were observed: the stage III group showed significantly higher WT/D, AVI, and FD values than the stage I group ( p 0.001). The positivity rate for the cuffing sign was higher in the stage II group compared to the stage I group ( p = 0.003). The combined parameters (WT/D + AVI + FD) achieved an AUC of 0.911, with a sensitivity of 92.3% and specificity of 88.6%, outperforming individual parameters ( p = 0.002). AVI positively correlated with the vascular calcification score ( p 0.001), while FD negatively correlated with lung volume ( p = 0.001). The interobserver intraclass correlation coefficient (ICC) for WT/D measurements reached 0.923, and the diagnostic concordance rate for stage III was 100%. Conclusion MPR technology can quantify structural distortions of the BVB in pneumoconiosis. The combined parameter model provides an objective imaging basis for the clinical staging of pneumoconiosis.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liu et al. (2026) studied this question.

synapsesocial.com/papers/69c8c0b0de0f0f753b39b901https://doi.org/10.3389/fmed.2026.1760122
Ask AI
Helpful
Bookmark
Share
View Full Paper