Key result
Post-TTVR acute hemodynamic instability linked to ~35% intrahospital mortality.
Why the study?
Transcatheter tricuspid valve replacement eliminates tricuspid regurgitation and causes acute hemodynamic changes, but it was unclear whether this leads to acute hemodynamic instability.
What is the frequency, outcome, and risk factors of acute hemodynamic instability in patients undergoing transcatheter tricuspid valve replacement?
What is the frequency, outcome, and risk factors of acute hemodynamic instability in patients undergoing transcatheter tricuspid valve replacement?
Acute hemodynamic instability is a life-threatening early complication occurring in 8.5% of TTVR patients, driven by factors like elevated left-sided filling pressures and impaired renal function, and is associated with exceedingly high intrahospital mortality.
Background Transcatheter tricuspid valve replacement (TTVR) eliminates tricuspid regurgitation, leading to acute hemodynamic changes. It is unclear whether this might lead to acute hemodynamic instability (AHI).Objectives The aim of this study was to report the frequency, outcomes, and risk factors of AHI following TTVR.Methods Patients undergoing TTVR at 5 international centers were included. AHI after TTVR was defined as class ≥ C shock according to the Society for Cardiovascular Angiography and Interventions classification.Results The study included 200 patients with a mean age of 78 ± 11 years (64% women). The frequency of AHI was 8.5%, and in all patients the onset was within 24 hours after the procedure. Compared with patients without postprocedural AHI, intrahospital mortality was significantly higher in AHI patients (35.2% vs 0.1%; P < 0.001). Univariate regression identified low glomerular filtration rate, reduced left ventricular ejection fraction, decreased ratio of tricuspid annular plane systolic excursion to mean pulmonary artery pressure, and elevated pulmonary capillary wedge pressure as significant factors of AHI.Conclusions AHI is a life-threatening complication in the early postprocedural period following TTVR. Elevated left-sided filling pressures, pulmonary hypertension, and impaired renal function are associated with an increased risk for AHI, suggesting that patient selection and preprocedural optimization are critical.
No takes yet. Share an insight, caveat, or question.
Kirchner et al. (2026) studied this question. Acute hemodynamic instability occurred in 8.5% of patients following transcatheter tricuspid valve replacement, resulting in significantly higher intrahospital mortality (35.2% vs 0.1%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: