Key result
Right-left cusp fusion linked to ~8-fold higher risk of significant post-TAVI paravalvular leak.
Why the study?
Do specific bicuspid aortic valve subtypes and aortic root morphologies predict the occurrence of more than mild paravalvular leak following TAVI?
Cohort (n=145)
No
Do specific bicuspid aortic valve subtypes and aortic root morphologies predict the occurrence of more than mild paravalvular leak following TAVI?
In patients with bicuspid aortic stenosis undergoing TAVI, right-left cusp fusion, self-expanding prostheses, extended sinotubular junction dimensions, and pre-existing atrial fibrillation independently predict an increased risk of more than mild paravalvular leak.
R-L cusp fusion may elevate PVL risk after TAVI in bicuspid stenosis; leaves open subtype-specific device strategies pending prospective validation.
BACKGROUND: Limited information exists on the impact of bicuspid aortic valve (BAV) type on paravalvular leak (PVL) occurrence following transcatheter aortic valve implantation (TAVI). AIMS: This study aimed to assess whether BAV type and aortic root morphology can predict the development and severity of PVL post-TAVI. METHODS: We retrospectively analyzed 145 patients with BAV stenosis who underwent TAVI at our center from January 2015 to December 2023. BAVs were classified based on the presence of raphes: 2-sinus BAV, fused BAV (right-left, right-noncoronary, left-noncoronary), and two raphes. RESULTS: The mean age was 77.4 (7.7) years, with 47.6% being men. Right-left (R-L) cusp fusion was associated with an increased incidence of greater than mild PVL (P = 0.02). Patients with more than mild PVL exhibited higher calcium score (4873 [3554-6514] vs. 3750 [2264-5900]; P = 0.03) and larger dimensions in the ascending aorta (39.8 [4.9] mm vs. 37.9 [5.2] mm; P = 0.045), sinotubular junction (STJ) long axis (33.7 [5.2] mm vs. 31.7 [4.2] mm; P = 0.02), and sinus of Valsalva (34.4 [4.6] mm vs. 32.6 [4.1] mm; P = 0.03) compared to those with ≤ mild PVL. Multivariable analysis showed independent predictors of more than mild PVL as the use of self-expanding prosthesis (P <0.001), STJ dimension (P <0.001), atrial fibrillation prior to TAVI (P = 0.003), and R-L cusp fusion (P = 0.02). CONCLUSIONS: The incidence of more than mild PVL varied with BAV subtypes and aortic root morphology. Independent factors increasing PVL risk included R-L cusp fusion, self-expanding prosthesis use, extended STJ short axis, and pre-existing atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Nieznańska et al. (2026) conducted a cohort in Bicuspid aortic valve stenosis (n=145). Right-left (R-L) cusp fusion bicuspid aortic valve vs. Other bicuspid aortic valve subtypes was evaluated on Occurrence of more than mild paravalvular leak (PVL) following TAVI (OR 7.7, 95% CI 1.34-44.4, p=0.02). Right-left cusp fusion in bicuspid aortic valve stenosis was independently associated with a significantly increased risk of more than mild paravalvular leak following TAVI (OR 7.7).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: