Key result
HRV domains correlate with VO2 max in asymptomatic individuals at high CVD risk.
Why the study?
The relationship between VO2 max and heart rate variability parameters in individuals at high cardiovascular risk without clinical diagnosis was unclear.
Cross-Sectional
Answers are grounded in this paper and cite their sources.
Higher VO2 max is associated with better heart rate variability parameters (rMSSD and SDNN index) in asymptomatic individuals at high cardiovascular risk.
Objective: max) in individuals at high risk of cardiovascular disease but without a clinical diagnosis. Methods: max and HRV parameters including standard deviation of normal-to-normal (NN) intervals over 24 hours, standard deviation of the averages of NN intervals in all 5-minute segments, standard deviation of NN intervals in 5-minute segments (SDNN index), root mean square of successive differences (rMSSD), percentage of successive NN intervals that differ by more than 50 ms, total power (TP), low frequency (LF), and high frequency (HF) were analyzed using Spearman correlation analysis. Results: max and rMSSD (rho = 0.122, p = 0.032) and SDNN index (rho = 0.184, p = 0.001). These associations remained statistically significant after adjusting for age using partial Spearman correlation analysis. Conclusions: max in asymptomatic individuals with high cardiovascular risk.
No takes yet. Share an insight, caveat, or question.
Hayıroğlu et al. (2026) conducted a cross-sectional in High risk for cardiovascular disease. VO2 max was evaluated on Correlation between VO2 max and HRV parameters (rho = 0.184, p=0.001). VO2 max was correlated with heart rate variability parameters, including rMSSD and SDNN index.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: