Demonstrates improved linearity of optical frequency-sweep in FMCW reflectometry, suggesting better measurement accuracy.
We propose and demonstrate a novel linearizing method of optical frequency-sweep of a laser diode for frequency-modulated continuous-wave (FMCW) reflectometry. In order to linearly sweep the optical frequency, we adopt a reference interferometer and an electric phase comparator. The interference beat signal of the reference interferometer is phase-compared with an external reference rectangular signal having a fixed frequency near the interference beat signal frequency by a lockin amplifier. The error signal from the lock-in amplifier is fed back to the modulating signal of the injection current of the laser. Thus, a phase-locked loop composed of optical and electric circuits can be established, and the beat signal frequency is locked to the frequency of the reference signal. The optical frequency of the laser diode is, therefore, excellently linearly swept in time. In order to experimentally confirm the linearity of the proposed method, we apply this frequency-swept laser diode to the FMCW reflectometry. Resultingy, the improvement of the linearity is estimated to be about 10 dB. And the theoretically limited spatial resolution of the FMCW reflectometry is achieved. The backscattered light in optical waveguide devices is measured by the FMCW reflectometry using the proposed light source, and the propagation loss of a single-mode glass waveguide is successfully evaluated.