Answers are grounded in this paper and cite their sources.
Examines how observer experience influences Cup:Disc ratio agreement in optometry, suggesting expertise enhances consistency among evaluators.
Background. The validity of the Cup:Disc (C:D) ratio as a clinical measure depends on the level of agreement among observers. In this study, we investigated the effect of observer experience on interobserver and intraobserver agreement in C:D ratio estimation. Methods. Nine 3rd‐year (Yr3) and nine 4th‐year (Yr4) optometry students and nine optometrists (Opt), determined C:D ratios from 26 optic disc photographs viewed monoscopically and stereoscopically. Observer agreement was investigated using weighted kappa (K W ) analysis. Results. Interobserver agreement was higher (p < 0.01) among optometrists than among 4th‐year students and higher (p < 0.01) among 4th‐year than among 3rd‐year students (mean K W : Opt = 0.61; Yr4 = 0.51; Yr3 = 0.39). Stereoscopic estimates of C:D ratios were higher (p < 0.0001) than monoscopic estimates, and interobserver agreement was higher (p < 0.001) when evaluating the vertical rather than the horizontal C:D ratio. Intraobserver agreement (mean K W : Opt = 0.67; Yr4 = 0.66; Yr3 = 0.62) did not vary significantly (p = 0.78) with experience. Conclusions. The extent to which an observer reproducibly assesses the C:D ratio from optic disc photographs (intraobserver agreement) does not increase with experience. However, the agreement between different observers in assessing the C:D ratio (interobserver agreement) increases with experience.
No takes yet. Share an insight, caveat, or question.
Hanson et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: