Measurements demonstrate specific vacuum characteristics of a getter for hydrogen in fusion installations, indicating its efficiency.
In this paper, the measured specific vacuum characteristics of a nonevaporable getter consisting of Ti–Zr–Al for hydrogen and its isotopes for use in thermonuclear fusion installations are presented. The vacuum system of neutral beam injectors requires hydrogen and deuterium pumping speed of millions of liters per second at a pressure of 10–5 Torr. Specific pumping speed of approximately 0.81 L/(s cm2) for hydrogen and 0.44 L/(s cm2) for deuterium were obtained for the Ti–Zr–Al getter, and the hydrogen sorption capacity was measured, which is greater than 6 L Torr/g.