A case report demonstrates improved pulmonary function in a patient with heart surgery using high-level PEEP and IMV, indicating careful management is essential.
A middle-aged man developed congestive heart failure and respiratory failure after coronary artery surgery. Mechanical ventilation with FI O 2 0.60 and PEEP of 15 cm H 2 O did not arrest pulmonary decline, but the PEEP was ruled out as a cause of deterioration and high PEEP of 30 cm H 2 O was tried. Lung compliance, PO 2 , and PCO 2 improved with high-level PEEP. To try to avert cardiovascular damage from the high PEEP, IMV was employed to lower mean intrathoracic pressure. Worsened mental status was noted after two days; high PEEP may have caused venous stasis and consequent cerebral edema. PEEP was discontinued after 13 days and the case was brought to a successful conclusion with no apparent residual pulmonary or neurologic dysfunction. It is suggested that the use of high-level PEEP should be accompanied by monitoring of cerebrospinal fluid pressure.
No takes yet. Share an insight, caveat, or question.
Gingold et al. (1976) studied this question.