How do different frequencies and amplitudes of mechanical ventilation affect spontaneous breathing patterns in anesthetized adults?
How do different frequencies and amplitudes of mechanical ventilation affect spontaneous breathing patterns in anesthetized adults?
Mechanical ventilation can entrain spontaneous breathing rhythms in anesthetized humans, demonstrating respiratory phase locking dependent on ventilator frequency and amplitude.
Answers are grounded in this paper and cite their sources.
May warrant attention to ventilator frequency in anesthetized patients; leaves open effects on clinical outcomes.
The coupling patterns between the rhythm of a mechanical ventilator and the rhythm of spontaneous breathing were studied in enflurane-anesthetized adult human subjects. The spontaneous breathing pattern was altered in response to different frequencies and amplitudes of forced lung inflations. A 1:1 phase locking (the frequency of the mechanical ventilator is matched by the frequency of spontaneous breathing with a fixed phase between the 2 rhythms) was observed in a range of up to +/- 40% of some of the subject's spontaneous breathing frequencies. During 1:1 phase locking, there were marked changes in the expiratory duration as measured from the electromyogram of the diaphragm. The phase relationship between onset of inflation and onset of inspiration depended on the frequency and amplitude of mechanical inflation. At ventilator settings that did not give 1:1 phase locking, other simple phase-locked patterns, such as 1:2 and 2:1, or irregular non-phase-locked patterns were observed. Reflexes arising from lung inflation, which may underlie the entrainment, are discussed in the context of these results.
No takes yet. Share an insight, caveat, or question.
Graves et al. (1986) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: