April 5, 2026Cancer Research0 citations

Abstract 7669: Automated multiplex profiling of human cytokines and autoantibodies using an Automated Assay Workstation.

View Full Paper
WLWen‐Rong LieSpectral Sciences (United States)BGBrooke GilliamLMLaura M. MarquardtSpectral Sciences (United States)

Key Points

  • The aim is to evaluate the effectiveness of an automated workstation for high-throughput cytokine and autoantibody profiling.
  • Utilized AAW™ for automated multiplex bead-based immunoassays
  • Profiled serum samples for cytokines using MILLIPLEX Human Cytokine Panels A and B
  • Conducted cancer autoantibody profiling with a 15-plex antigen-coated bead panel
  • Employed Luminex instrumentation for analysis
  • Automated liquid handling, standard curve preparation, and plate setup
  • Demonstrated high correlation (R2 > 0.95) between automated and manual cytokine analysis
  • Achieved processing of 2-3 assay plates daily with reduced hands-on time
  • Minimized human error leading to increased assay reliability and efficiency
  • Confirmed robustness and reproducibility of multiplex analysis for cancer research

Abstract

Abstract Automated multiplex bead-based immunoassays were performed using an AAW™ Automated Assay Workstation for high-throughput profiling of immune factors and cancer autoantibodies. Human serum cytokine analysis was conducted with MILLIPLEX Human Cytokine Panel A and Panel B kits (48-plex, overnight protocol), and across cytokines spanning a broad dynamic range, automated-to-manual correlation coefficients (R2) were greater than 0.95 with regression slopes between 0.80 and 1.20. Cancer autoantibody profiling used a 15-plex antigen-coated bead multiplex panel on sera from various cancer types and healthy donors (n=96 total samples). The AAW™ workstation automates all critical liquid handling, standard curve preparation, sample transfer, reagent dispensing (matrix solution, Assay Buffer, Standards, QCs, samples, and Beads), and plate setup with robotic lidding. Assay plates were washed off-deck on an automatic plate washer and analyzed with a Luminex instrument. The automated protocol enabled processing of 2-3 plates daily, with streamlined setup which significantly reduce hands-on time. Minimizing manual interventions reduced opportunities for human errors, resulting in greater reliability and efficiency for high-throughput applications. The AAW™ performance confirms robust, reproducible, and scalable multiplex analysis for cancer and immunology research. Citation Format: Wen-Rong Lie, Brooke Gilliam, Laura Marquardt, Mark Pawlicki, Ernest Mueller, Xiuyuan Zhang, Nathanael Ellis, Todd Hendrich, Linda Meeh, Scott Keefer, Qiang Xiao, . Automated multiplex profiling of human cytokines and autoantibodies using an Automated Assay Workstation abstract. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 7669.