Research analyzes shear performance of self-tapping screws in cold-formed steel, indicating implications for structural integrity.
As an important connector in cold-formed steel structures, the shear performance and failure modes of self-tapping screws directly affect the mechanical properties and failure modes of the structure. At present, researchers worldwide have focused mainly on the shear capacity of single self-tapping screws, while the studies related to the shear-slip constitutive relationship are scarce. Therefore, this paper summarized and analyzed both previous shear test results of single self-tapping screws and the tests conducted in this study. Using the XTDIC three-dimensional full-field strain measurement and analysis system, an in-depth analysis of the shear failure mechanism of self-tapping screw connections in cold-formed steel was conducted. Considering the effects of screw diameter, plate thickness, and material properties, two shear-slip constitutive models corresponding to the two major shear failure modes of such connections were proposed, which showed good agreement with the experimental results.
No takes yet. Share an insight, caveat, or question.
LI et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: