Does the Edwards SAPIEN 3 valve increase the incidence of permanent pacemaker implantation compared to the XT valve in patients undergoing TAVI?
Does the Edwards SAPIEN 3 valve increase the incidence of permanent pacemaker implantation compared to the XT valve in patients undergoing TAVI?
Answers are grounded in this paper and cite their sources.
Higher pacemaker rates with the SAPIEN 3 valve compared to the XT valve are driven by deep valve implantation, suggesting that a higher implantation technique may prevent this complication without increasing paravalvular leak.
The S3-THV was associated with a higher incidence of PPMI compared to the XT-THV. In the S3-THV group, pacemaker implantation was strictly associated with deep valve implantation. An implantation technique involving higher initial placement of the central marker (from 0 to 3 mm above the base of the aortic cusps) and, as a consequence, higher final valve depth might help in preventing post-TAVI PPMI with the S3-THV, without affecting the risk of paravalvular leak.
No takes yet. Share an insight, caveat, or question.
Tarantini et al. (2015) studied this question.