Does a Jacobian matrix-based interpretability tool for AI ECG classification correlate with gold standard interpretations by electrophysiologists?
A novel interpretability tool for AI-based ECG classification demonstrated high correlation with expert electrophysiologist interpretations, potentially facilitating the clinical integration of AI ECG models.
Despite the high accuracy of AI-based automated analysis of 12-lead ECG images for classification of cardiac conditions, clinical integration of such tools is hindered by limited interpretability of model recommendations. We aim to demonstrate the feasibility of a generic, clinical resource interpretability tool for AI models analyzing digitized 12-lead ECG images. To this end, we utilized the sensitivity of the Jacobian matrix to compute the gradient of the classifier for each pixel and provide medical relevance interpretability. Our methodology was validated using a dataset consisting of 79,226 labeled scanned ECG images, 11,316 unlabeled and 1807 labeled images obtained via mobile camera in clinical settings. The tool provided interpretability for both morphological and arrhythmogenic conditions, highlighting features in terms understandable to physician. It also emphasized significant signal features indicating the absence of certain cardiac conditions. High correlation was achieved between our method of interpretability and gold standard interpretations of 3 electrophysiologists.
Глинер et al. (Mon,) studied this question.