Answers are grounded in this paper and cite their sources.
A new type of corrosion-resistant alloyed-steel rebar, Cr10MoV, was researched using techniques such as corrosion electrochemistry, X-ray computed tomography, and zero resistance ammeter to systematically study the macro-cell corrosion behavior and corrosion resistance of alloyed-steel rebar in mortar and concrete samples induced by chloride ion concentration in the marine environment. The macro-cell corrosion characteristics and development patterns induced by chloride ion concentration in alloyed-steel rebar were preliminarily revealed. In the macro-cell corrosion system of rebar mortar samples induced by 29 times chloride ion concentration, the corrosion current density of the alloyed-steel rebar combination stabilizes at 1.6–2.4 μA/cm 2 , which is only one-third of that of the carbon-steel rebar combination, while the dissimilar steel rebar combination stabilizes at 0–0.4 μA/cm 2 . Alloyed-steel rebar and carbon-steel rebar are configured in high concentration and low concentration chlorine salt areas, respectively. With the help of high corrosion resistance, the long-term stable corrosion resistance of alloyed-steel rebar is ensured. The potential difference between carbon-steel rebar and alloyed-steel rebar is reduced to weaken the driving force of macro-cell corrosion. It is a useful way to inhibit the macro-cell corrosion of dissimilar steel rebar and ensure the high corrosion resistance and durability of marine reinforced concrete structures.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: