Cervical total disc replacement with ProDisc C demonstrated a significant and maintained improvement of all clinical outcome parameters at a follow-up of ≥10 years. The present long-term data reveal that with an exceptionally low implant-related reoperation rate and low symptomatic adjacent segment degeneration rate, cTDR may be regarded as a safe and viable treatment option.