Answers are grounded in this paper and cite their sources.
This paper is concerned with a theoretical study of the control of a single-capacity process with dead-period lag. Characteristic equations corresponding to the application of proportional, proportional-plus-derivative, proportional-plus-reset, and proportional-plus-reset-plus-derivative responses are used to graph the controller parameters necessary to obtain a desired degree of stability. The degree of stability is taken to be associated with the amplitude ratio of the lowest-frequency harmonic mode. Effects of the various controller parameters are shown and a method is suggested to determine the adjustable parameters for a desired degree of stability.
No takes yet. Share an insight, caveat, or question.
Cohen et al. (1953) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: