In the high-frequency (HF) signal injection based position sensorless permanent magnet synchronous motor (PMSM) drives, there is an estimated position error caused by the cross-saturation effect and other factors. In order to suppress the position error, an HF injection angle self-adjustment based online suppression method is proposed in this letter. By tracking the sign of the increment of the absolute back electromotive force in the estimated frame, the criterion of the HF injection angle self-adjustment can be determined online and the position error can be mitigated effectively. This method can avoid the offline measurement or the variation of the operating state, which has a satisfactory suppression effect for the position error under different operating conditions. The effectiveness is verified by experiments on a 2.2-kW PMSM drive platform.