Answers are grounded in this paper and cite their sources.
Screw stability depends on the structural characteristics of the pedicle. The pedicle was denser in the subcortical bone, in which the threads of the screw engage, than in trabecular bone. In osteoporosis, bone mineral density was not as dense even in the outer layer, and the cortex was thinner than normal. A larger screw would not enhance screw stability and may break the thin cortex in osteoporotic vertebrae.
No takes yet. Share an insight, caveat, or question.
Hirano et al. (1997) studied this question.