Percutaneous snaring and removal of a malpositioned, overhanging ostial RCA stent followed by OCT-guided PCI is a feasible and effective alternative to high-risk CABG.
Answers are grounded in this paper and cite their sources.
Supports percutaneous retrieval as bailout in ostial stent malposition; hypothesis-generating and leaves open role versus CABG.
We present a complex case of a 77-year-old high-surgical-risk patient with refractory angina due to severe in-stent restenosis (ISR) of a malpositioned right coronary artery (RCA) ostial stent protruding into the Aorta. Despite prior PCIs, including overlapping drug-eluting stents (DES), progressive ISR led to debilitating symptoms. Diagnostic imaging revealed an 8–10 mm aortic overhang of the RCA stent, complicating catheter engagement. A multidisciplinary team pursued percutaneous management to avoid high-risk CABG. Using femoral access and a temporary pacemaker, a malpositioned stent was successfully snared and removed. Subsequent OCT-guided PCI involved distal 3.0 × 32 mm and ostial 3.5 × 16 mm PROMUS DES deployment, optimized with intravascular imaging. The procedure restored TIMI III flow, resolving symptoms without complications. This case demonstrates the successful percutaneous retrieval and imaging-guided PCI for aortic-ostial ISR, highlighting the importance of careful planning, advanced interventional techniques, and a multidisciplinary approach to minimize the need for invasive surgery in high-risk patients.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2025) studied this question.