Longitudinal stent deformation is a mechanical complication that carries a risk of stent thrombosis and was observed more frequently with the Promus Element stent in this retrospective analysis.
Answers are grounded in this paper and cite their sources.
May warrant thrombosis vigilance with Promus Element; leaves open causal mechanisms and design mitigation in prospective studies.
Longitudinal stent deformation can occur secondary to a variety of mechanisms and identification is important as, left untreated, it may be associated with a risk of stent thrombosis. Although seen with several different stents, in our series it was more commonly observed with the Promus Element stent.
No takes yet. Share an insight, caveat, or question.
Williams et al. (2012) studied this question.