A high temperature superconducting (HTS) coil without turn-to-turn insulation is proposed for the field coil of a wind turbine. In the case of the field coil, epoxy impregnation is generally necessary to protect the coil from mechanical disturbances by time-varying magnetic fields and rotational vibrations to provide high mechanical integrity. This study examined the thermal and electrical stabilities of non-insulated GdBCO racetrack pancake coils impregnated with CTD-521, Stycast 2850 FT, and paraffin through cool down, over-current, and repetitive cooling tests. Among the three epoxy impregnated coils, the Stycast 2850 FT-impregnated coil exhibited the best thermal and electrical stabilities during over-current testing. In repetitive cooling conditions, the CTD-521-impregnated coil exhibited less degradation of its superconducting property due to the well-matching of the thermal contraction between the GdBCO racetrack pancake coil and the epoxy.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: