In this article, we experimentally demonstrate an all-fiber optical amplifier using Bi-doped phosphosilicate fiber (BPSF) operating in both the O-band and the E-band, providing >20 dB gain from 1345 to 1460 nm for an input signal power of −23 dBm. A maximum gain of 31 dB with a noise figure (NF) of 4.8 dB was achieved at 1420 nm for −23 dBm input signal, whereas for an input signal power of −10 dBm it was 26 dB with a NF of 5.3 dB. The in-band OSNR of the proposed Bi-doped fiber amplifier (BDFA) was >22 dB from 1345 to 1460 nm for a −23 dBm input signal. The gain coefficient was found to be 0.04 dB/mW for a −23 dBm input signal. Also, the temperature dependent gain and NF performance of the BDFA within −40 to +60 °C were characterized. The temperature-dependent-gain (TDG) coefficient for a −23 dBm input signal was found to be −0.015 dB/°C at a signal wavelength of 1420 nm where the BDFA gain is maximum, while for an input signal power of −10 dBm it was −0.01 dB/°C at 1420 nm. The TDG coefficient of the proposed BDFA from 1350–1460 nm was in the range from −0.079 to −0.008 dB/°C. The BDFA gain and NF performance were also measured and compared using BPSFs with different unsaturable loss (UL) characteristics.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: