In this paper, we evaluate the thermal response of graphite samples to high-power continuous wave laser heating. Experimental work is performed at the Aerospace Laboratory for Lasers, Electromagnetics, and Optics (ALLEMO) at Texas A&M University. Experimental results are compared to the results of an in-house finite-volume heat transfer model. The model demonstrates agreement with steady-state experimental surface temperature to within 1% of the measured temperature for incident beam powers up to 1450 W. The incorporation of active mesh deformation allows for the prediction of sublimation and the resulting beam penetration depth to within 5% of the measured value, even for depths exceeding 5 mm. A subsequent test showed higher error (11%), but the same sample was used for both tests, and previous damage likely impacted results. The model demonstrates strong agreement with experimental data, but we believe incorporation of beam interaction with the outgassing carbon vapor, particulate re-deposition, and small-angle beam divergence can further improve the results.